Corrosion probe system consists of:
Non-Tee Access Fitting Assembly
Non- Tee access fitting assembly consists of access fitting body,
hollow plug assembly, and protective cover with NPT threaded hole.
Corrosion Probe
Corrosion monitoring methods widely used in Oil & Gas Industries
are ER and LPR corrosion monitoring method. ER/LPR probe is equipped
with MIL-C50 15 connector style to connect to the corrosion data
logger. ER/LPR probe is inserted and locked into the hollow plug
assembly with NPT thread.
Extension Adapter
Extension adapter is required to establish connection between the
ER/LPR probe and corrosion data logger. Extension adapter is equipped
with female and male MIL-C-5015 connectors. Extension adapter is
connected to the ER/LPR probe connector and locked into the protective
cover with swage lock.
Corrosion Data Logger
Corrosion data logger ranges from portable, continuous on-line, and
continuous real-time data loggers. Portable corrosion data logger
allows operator to collect corrosion data and view it with PC using
Windows Application Software. Continuous on-line corrosion data logger
features field mounted, battery powered, and manual data retrieval
using an Up- loader. Continuous real-time corrosion data logger
features field mounted, externally powered, and automatically data
transmitting to viewing unit. Corrosion data logger is connected to the
extension adapter with cable.